Accident Summary Nr: 79788.015 - Employee drowns when riding lawn mower rolls over into pond

Accident Summary Nr: 79788.015 -- Report ID: 0524530 -- Event Date: 09/23/2015
Inspection NrDate OpenedSICNAICSEstablishment Name
1094154.01509/24/2015561730D.D.M. Investments, Inc Dba Wieland'S Lawn Services

Abstract: At 3:26 p.m. on September 23, 2015, Employee #1 was working for a landscaping service. He and a coworker were cutting lawns in a large residential subdivision. The weather was 21 degrees Celsius (69 degrees Fahrenheit), with 78 percent relative humidity. Visibility was 16 kilometers (10 miles), with calm winds out of the east-southeast. At approximately 8:00 a.m. that day, Employee #1 and his coworker started mowing the lawns in the residential subdivision. Employee #1 was operating a SCAG Turf Tiger Model STT61V-791 zero-radius turn commercial mower, with Serial Number H9600165. This was a riding mower, on which the operator sat down to operate the mower. The coworker was operating a stand-behind-style mower (a "sulkie," if it was a riding mower). Behind the houses in the subdivision was a large pond. Employee #1 was mowing an area around the pond in the subdivision. As was common, the two workers were not mowing in the same area. As Employee #1 operated his mower around the edge of the pond, a wheel slid off the grass. As a result, the mower rolled over into the pond. Employee #1 was pinned beneath the mower in water approximately 0.8 meters (30 inches) deep. The mower's roll-over protection system (ROPS) was engaged in the upright position. Employee #1 was not wearing a seat belt and he drowned.

Keywords: Drown, Drowning, Inexperience, Lawn Mower, ROPS, Riding on Equipment, Roll-Over, Seat Belt, Slippery Surface, Slope, Sloping, Walking Surface, Water, Work Rules

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1094154.015 18 M Fatality

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close