Accident Summary Nr: 78895.015 - Employee is asphyxiated and killed after entering storage ta

Accident Summary Nr: 78895.015 -- Report ID: 0521100 -- Event Date: 08/14/2015
Inspection NrDate OpenedSICNAICSEstablishment Name
1085311.01508/17/2015112120Matsche Farms Inc.

Abstract: At 4:45 p.m. on August 14, 2015, Employee #1, a maintenance worker, was lowered into a 12 foot tall 8,000 gallon polyethylene tank using a rope with a loop to stand on and the other end connected to a rough terrain forklift operated by the manager of the farm. The tank was used to store liquid whey that was added to the animal feed. Employee #1 was instructed to open a broken ball valve so the liquid whey would flow faster out of the tank. Employee #1 lost consciousness and was found face down in the tank by the manager. Employee #1 was asphyxiated and died due to a low oxygen environment and probable high concentrations of fermentation gases.

Keywords: Agriculture, Asphyxiated, Confined Space, Powered Industrial Vehicle, Storage Tank

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 1085311.015 32 M Fatality Farm workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close