Accident Summary Nr: 786301 - Eight employees exposed to carbon monoxide

Accident Summary Nr: 786301 -- Report ID: 1054191 -- Event Date: 10/01/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11572103710/01/199154110Albertsons Inc

Abstract: A four-member cleanup crew that was working the midnight shift to complete a biannual operation used a gas-fueled pressure washer indoors without benefit of engineering or administrative controls, or personal protective equipment. The washer ran indoors for approximately four hours. Interviews with employees indicate that the washer may not have been well maintained (emitting smoky exhaust, noisy, stalling), and that two on-duty supervisors did not respond to this information; nor to the employees' reporting symptoms that included nausea, lightheadedness, dizziness; nor to an employee lying on the floor in the work area. Employees #1 through #8, four members of the cleanup crew and members of the midnight freight crew, inhaled carbon monoxide. They were hospitalized. A blood sample on Employee #1 showed a carboxyhemoglobin level of 23.8 percent.

Keywords: INADEQUATE MAINT, PPE, WORK RULES, TOXIC ATMOSPHERE, NAUSEA, DIZZINESS, EXHAUST FUMES, CARBOXYHEMOGLOBIN, OVEREXPOSURE, CARBON MONOXIDE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 115721037 Hospitalized injury Asphyxia Occupation not reported
2 115721037 Hospitalized injury Asphyxia Occupation not reported
3 115721037 Hospitalized injury Asphyxia Occupation not reported
4 115721037 Hospitalized injury Asphyxia Occupation not reported
5 115721037 Hospitalized injury Asphyxia Occupation not reported
6 115721037 Hospitalized injury Asphyxia Occupation not reported
7 115721037 Hospitalized injury Asphyxia Occupation not reported
8 115721037 Hospitalized injury Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.