Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 785436 - Employee's arm severed by conveyor belt

Accident Summary Nr: 785436 -- Report ID: 1054111 -- Event Date: 11/13/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
10827486111/13/199051460Pacific Sea Food Co Inc

Abstract: Employee #1, of Pacific Seafood Co., reached into the in-running nip point at the infeed head pulley on a conveyor that carries oyster shells to a drop box. He intended to remove a shell that had dropped onto the conveyor's return section, but his glove caught between the pulley and the belt, and his hand and arm were pulled up and around the pulley. The pulley severed the employee's arm at or near the elbow.

Keywords: SEVERED, AMPUTATED, BELT, GLOVE, WORK RULES, CAUGHT BETWEEN, CONVEYOR, ARM, NIP POINT, PULLEY

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 108274861 Hospitalized injury Amputation Butchers and meat cutters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close