Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 783498 - Employee's fingers amputated in die machine

Accident Summary Nr: 783498 -- Report ID: 0452110 -- Event Date: 11/02/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
12460001611/11/199330890Owens Illinois Label & Carrier Division Inc

Abstract: On October 9, 1993, Employee #1 reached his right hand through a die to dislodge the webbing that was hanging on the feed rollers. With his left hand, he attempted to depress the emergency stop button to ensure that the machine would not start. Instead, he depressed the machine's jog button. This activated the machine and caused it to amputate four of Employee #1's fingers.

Keywords: DIE, AMPUTATED, FINGER, WORK RULES, CAUGHT BY, EMERGENCY STOP, LOCKOUT, ROLLER--MACH/PART, INATTENTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 124600016 Hospitalized injury Amputation Punching and stamping press machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.