Accident Summary Nr: 782714 - Employee's four fingers amputated in power press

Accident Summary Nr: 782714 -- Report ID: 0452110 -- Event Date: 09/03/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
12379925609/20/199336990Overhead Door Corporation

Abstract: At approximately 8:30 p.m. on September 3, 1993, Employee #1 was operating a Heller-Sutherland model Mark 88-II, serial #0105, part-revolution mechanical power press. Continuous mode was selected on the selector switch. The label indicating continuous mode was missing. Because the arming button was inadvertently pushed, when Employee #1 attempted to remove a part from the die, the press continued to cycle. All four fingers of her right hand were amputated.

Keywords: DIE, AMPUTATED, INADEQUATE MAINT, POWER PRESS, FINGER, WORK RULES, POINT OF OPERATION, SWITCHGEAR, INATTENTION, WARNING SIGN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 123799256 Hospitalized injury Amputation Punching and stamping press machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.