Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 775031 - Two employees killed in fall from scaffold

Accident Summary Nr: 775031 -- Report ID: 0627700 -- Event Date: 08/29/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
10058181808/29/198817410Pudge Wright Masonary

Abstract: At approximately 9:10 a.m. on August 29, 1988, Employees #1 and #2 were working on a 24 ft long two point suspension scaffold that was elevated to 60 ft. The scaffold was suspended by outrigger beams that were 17 ft apart. They were resting on cinder and counterweighted by sandbags, but there were no tiebacks or secondary means of anchorage. One of the outriggers began to tip, causing Employees #1 and #2 to fall. Both were killed. A coworker was able to grab and hold onto a ledge until he was rescued. All three employees were wearing safety belts but they were not tied off.

Keywords: OUTRIGGER, UNSECURED, WORK RULES, CONSTRUCTION, FALL, TIE-OFF, OVERTURN, SCAFFOLD

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 100581818 Fatality Concussion Occupation not reported
2 100581818 Fatality Concussion Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close