Accident Summary Nr: 773879 - ELECTRIC SHOCK - GROUND FAULT IN ROUTER

Accident Summary Nr: 773879 -- Report ID: 0625400 -- Event Date: 06/27/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11950843007/11/199115210Rayco, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
11950847107/11/199117310Chamerlin Electric Co.
Inspection NrDate OpenedSICNAICSEstablishment Name
11950851307/01/199117420Jose Eduardo Martinez

Abstract: A DRYWALL INSTALLER WAS CUTTING DRYWALL WITH A METAL-CASED PORTABLE ROUTER. THE ROUTER HAD A THREE-CONDUCTOR POWER SUPPLY CORD THAT HAD BEEN SPLICED TO A TWO-CONDUCTOR CORD AND ATTACHMENT PLUG. AS A RESULT, THE ROUTER WAS NOT GROUNDED. THE ATTACHMENT PLUG WAS CONNECTED TO AN EXTENSION CORD SET THAT WAS STRETCHED OUT TO 89 FEET. (THE 120-VOLT CIRCUIT WAS NOT PROTECTED BY A GROUND-FAULT CIRCUIT INTERRUPTER.) THE EMPLOYEE WAS ELECTROCUTED BY AN APPARENT GROUND FAULT IN THE ROUTER.

Keywords: ELECTRICAL, GROUND FAULT, EQUIPMENT GROUNDING, ELEC PORT TOOL--MISC, E GI V, ELECTROCUTED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 119508430 Occupation Not Listed
2 119508471 Occupation Not Listed
3 119508513 Fatality Electric Shock Drywall installers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.