Accident Summary Nr: 772970 - Employee dies after being struck by oil well horsehead

Accident Summary Nr: 772970 -- Report ID: 0627700 -- Event Date: 09/09/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
10874232109/10/199213890Stride Well Service
Inspection NrDate OpenedSICNAICSEstablishment Name
10874180209/10/199213110Continental Resources, Inc.

Abstract: Employee #1 and his coworkers on an oil well servicing crew had completed replacing a well's pump and reassembling of its pumping unit when the unit's electrical power source was interrupted. This rendered the unit inoperative and required the use of the service rig to simulate the unit's movement in testing the pump. The rig's hoisting capability was to. The rig was connected to the well. Employee #1 grasped a chain to restrain the unit's well-connecting hardware to keep it from interfering with the test. He was standing on the unit base almost directly under the unit's horsehead. As the rig operator started the first upstroke, a connector on the hoisting line caught the horsehead, causing it to dislodge and fall. A bolt to restrain the horsehead to the unit had not been installed. Employee #1 was struck in the head by the horsehead as he tried to evade it. He died shortly thereafter from a crushed head and massive bleeding.

Keywords: HEAD, LOSS OF BLOOD, WORK RULES, BOLT, WELL SERVICE RIG, HOISTING MECHANISM, UNSECURED PANEL, CRUSHED, OIL WELL SERVICING, STRUCK BY

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 108742321 Fatality Fracture Occupation not reported
2 108741802 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.