Accident Summary Nr: 772921 - EMPLOYEE ASPHYXIATED BY ARGON GAS

Accident Summary Nr: 772921 -- Report ID: 0627700 -- Event Date: 05/16/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
10886273105/18/199237240Chromalloy Division-Oklahoma
Inspection NrDate OpenedSICNAICSEstablishment Name
10752882005/18/199237240Chromalloy Division-Oklahoma

Abstract: ON THE MORNING OF MAY 16, 1992, EMPLOYEE #1 AND ANOTHER WORKER HAD BEGUN SETTING UP THE BELL FURNACE FOR A DIFFUSED ALUMINIDE COATING OF AIRCRAFT ENGINE TURBINE BLADES. THE SETUP INCLUDED HOOKING UP ARGON LINES, LOADING THE FURNACE, AND ATTACHING LOW VOLTAGE THERMOCOUPLES. AT 1:20 PM, THE SETUP WAS THOUGHT TO BE COMPLETE AND THE RUN WAS INITIATED. EMPLOYEE #1 LEFT THE PLANT TO GO HOME, SHOWER, AND CHANGE CLOTHING. AT 2:10 PM, EMPLOYEE #1 RETURNED TO WORK AND NOTICED THAT THE FURNACE WAS NOT POWERING UP WITH OVEN HEAT. HE FAILED TO NOTICE, HOWEVER, THAT THE HEAT ENABLE SWITCH ON THE CONTROL PANEL WAS OFF. EMPLOYEE #1 WENT TO THE FURNACE TO CHECK THE ELECTRICAL THERMOCOUPLES LOCATED JUST BELOW THE FLOOR ON THE PIT WALL AND ON THE SIDE OF THE FURNACE. EMPLOYEE #1 WAS ASPHYXIATED BY ARGON GAS AND FELL 7 FEET INTO THE FURNACE PIT, DISCONNECTING THERMOCOUPLE LINES #2 AND #5. AT 2:20 PM, THE SECURITY GUARD NOTICED EMPLOYEE #1 LYING IN THE BOTTOM OF THE PIT, AND SUMMONED HELP. THE AREA SUPERVISOR AND OTHER EMPLOYEES USED SCBA AND AN ESCAPE RESPIRATOR TO REMOVE EMPLOYEE #1 FROM THE PIT. CPR WAS STARTED UNTIL THE FIRE DEPARTMENT ARRIVED AT 2:31 PM. AT 2:45 PM, THE AMBULANCE LEFT WITH EMPLOYEE #1. ANOTHER EMPLOYEE CHECKED THE OXYGEN ALARM, NOTICING THE FUSE IN THE BOTTOM OF THE ALARM BOX. THE EMPLOYEE RE-INSTALLED THE FUSE, THE ALARM SOUNDED AND THE GAUGE READ 6 PERCENT OXYGEN. LATER IN THE DAY, EMPLOYEE #1 EXPIRED AT MIDWEST CITY HOSPITAL.

Keywords: FURNACE, OXYGEN DEFICIENCY, RESPIRATORY, ASPHYXIATED, CONFINED SPACE, WORK RULES, PIT, SET UP, ARGON, INATTENTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 108862731 Fatality Asphyxia Occupation not reported
2 107528820 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close