Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 772509 - Three employees killed in frac tank by fumes

Accident Summary Nr: 772509 -- Report ID: 0627700 -- Event Date: 08/21/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
10750410208/22/199013890Midway Rental Service, Inc Dba/Mangum Oilfield
Inspection NrDate OpenedSICNAICSEstablishment Name
10750409408/22/199065190One Ok Resources Company
Inspection NrDate OpenedSICNAICSEstablishment Name
10750410208/22/199013890Midway Rental Service, Inc Dba/Mangum Oilfield

Abstract: Apparently Employee #1 was atop an oil field frac tank that contained drilling mud, and which had sat on-site for 60 days. He was using a water hose to dilute the mud for easier pump removal into a tank truck for disposal. He was overcome as he either leaned into or over the tank hatch opening to inject the water into the mud. Employees #2 and #3 then entered the tank, either one at a time or together, to rescue the first employee. One employee died from methane gas inhalation and two apparently were overcome by the gas and fell into the drilling mud and drowned. This frac tank differed from the others they had already emptied in that, because it did not have a front hatch opening, it had to be diluted from the top hatch. No respirators were on-site because the employees were not entering the tanks to do the job.

Keywords: WORK RULES, TOXIC FUMES, OVEREXPOSURE, RESPIRATOR, CONFINED SPACE, FRAC TANK, NATURAL GAS, FALL, OIL WELL SERVICING, DROWN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 107504102 Fatality Asphyxia Occupation not reported
2 107504094 Occupation Not Listed
3 107504102 Fatality Asphyxia Occupation not reported
4 107504102 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.