Accident Summary Nr: 772384 - One employee dies, one ill from exposure to toxic gas

Accident Summary Nr: 772384 -- Report ID: 0627700 -- Event Date: 06/30/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
10906492307/01/199413890Charles O. Pierce Trucking Co.
Inspection NrDate OpenedSICNAICSEstablishment Name
10906493107/01/199413110Nadel & Gussman Oil Company
Inspection NrDate OpenedSICNAICSEstablishment Name
10906605008/04/199429510Vance Brothers Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
10906608407/01/199413890Charles O. Pierce Trucking Co.

Abstract: A black substance accumulates in the pipelines of the injection wells that are used in an oil field water-flood operation and occasionally has to be removed. Hydrochloric acid (HCl) is pumped through the pipelines to dissolve the black matter. On June 30, 1994, Employee #1, the employer, pumped HCl through a pipeline that was 3,500 to 4,000 feet long. The acid was taken to the location in one tank truck and another tank truck was positioned to receive the acid. As the acid passed through the pipeline, it reacted with the calcium sulfide and/or iron sulfide in the black matter and created hydrogen sulfide (H2S). After the acid had been pumped through the pipeline and into the tank truck, the pump on the receiving tank truck was used to suck any remaining fluid from the hose. The pump evacuated H2S from the tank and out of the tank vent. The H2S created a lethal concentration outside the vent. Employee #1, the truck driver, walked into the vapor and immediately lost consciousness and died. Employee #2 attempted to assist his boss and was overcome by the toxic gas but recovered.

Keywords: UNCONSCIOUSNESS, TOXIC FUMES, HYDROCHLORIC ACID, VENTILATION, HYDROGEN SULFIDE, GAS, OIL WELL SERVICING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 109064923 Fatality Poisoning(Systemic) Occupation not reported
2 109064931 Hospitalized injury Poisoning(Systemic) Occupation not reported
3 109066050 Occupation Not Listed
4 109066084 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.