Accident Summary Nr: 768358 - Employee crushed to death by falling concrete panel

Accident Summary Nr: 768358 -- Report ID: 0626300 -- Event Date: 05/20/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
10355680905/21/199317910Reinforced Earth Company
Inspection NrDate OpenedSICNAICSEstablishment Name
10355679105/21/199316220Granite Construction Company

Abstract: Precast panels of reinforced concrete were manufactured in Waco, Texas, and transported by semi-truck to a highway construction site in Rockwall. The panels were 15 feet long, 4 feet wide and 5 1/2 inches thick, and set up on edge, tilted inward at the top, and chained and boomered for truck shipment. The tilt angle was built into the shipment rack which used 4 inch by 6 inch members and 55 gallon concrete-filled drums to create a lean-up angle of about 6 degrees with the vertical plane. The center of gravity of the 3,700 pound panel acts to balance the corner fulcrum point at about 6 1/3 degrees. The truck parked on a 2 percent grade highway and the first panel was taken from the high side of the truck, leaving it still higher by 1 inch and resulting in a decrease of the lean-up angle by about 2 degrees. Employee #1, the driver of the truck, stepped off the truck bed, possibly holding onto the panel on the low side, onto a traffic control barrier about 24 inches lower than the truck bed. The panel on the low side fell on him, fatally crushing his head and body.

Keywords: HEAD, WORK RULES, UNSECURED PANEL, CONCRETE PANEL, CONSTRUCTION, CRUSHED, STRUCK BY, FALLING OBJECT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 103556809 Fatality Concussion Occupation not reported
2 103556791 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close