Accident Summary Nr: 767509 - Three employees die of asphyxia in confined space

Accident Summary Nr: 767509 -- Report ID: 0626300 -- Event Date: 06/11/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
10754943806/12/199273630Onco Enterprises Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
10754944606/23/199216230Conex Construction

Abstract: Employees #1, #2, and #3 were inspecting and repairing newly constructed and operational sewer lines. It is theorized that Employee #2 fell into the manhole as he opened it and Employees #1 and #3 attempted to rescue him. Employees #1, #2, and #3 all died of asphyxia. Testing equipment was present and used in all other documentable cases, but it was not used this time. There was no forced ventilation, no rescue equipment, no air supply, and no competent person on site.

Keywords: SEWER, ASPHYXIATED, WORK RULES, TEST EQUIPMENT, MANHOLE, REPAIR, VENTILATION, CONFINED SPACE, CONSTRUCTION, FALL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 107549438 Fatality Asphyxia Occupation not reported
2 107549438 Fatality Asphyxia Occupation not reported
3 107549438 Fatality Asphyxia Occupation not reported
4 107549446 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.