Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 766204 - HAND FRACTURED IN PASTA MACHINE HOPPER

Accident Summary Nr: 766204 -- Report ID: 0931400 -- Event Date: 12/18/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
10237911212/18/198754110Alpha Beta Supermarket #24

Abstract: EMPLOYEE #1 WAS CLEANING A PASTA MACHINE AT THE TIME OF THE ACCIDENT. SHE HAD LIFTED THE INTERLOCKED COVER TO RETRIEVE SOME RESIDUAL FOOD IN THE HOPPER. THERE IS A SHAFT WITH BLENDING TINES IN THE HOPPER. SHE HAD THE HINGED COVER OPEN WHEN THE SHAFT STARTED TURNING. HER LEFT HAND WAS CAUGHT BETWEEN THE TINES AND THE INSIDE OF THE HOPPER. A SERVICE COMPANY CALLED IN TO LOOK AT AND REPAIR THE INTERLOCK STATED THAT THE FAILURE OCCURRED BECAUSE OF EXCESSIVE WEAR TO THE CAM AND FOLLOWER.

Keywords: FRACTURE, CLEANING, INTERLOCK, LOCKOUT, HAND, HOPPER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 102379112 Hospitalized injury Fracture Miscelaneous food preparation occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.