Accident Summary Nr: 76467.015 - Two employees are killed in fall from platform suspended by

Accident Summary Nr: 76467.015 -- Report ID: 0625500 -- Event Date: 04/29/2015
Inspection NrDate OpenedSICNAICSEstablishment Name
1060347.01504/30/2015928120U.S. International Boundary & Water Commission

Abstract: At 11:30 a.m. on April 29, 2015, two employees were preparing to power wash metal gates on the downstream side of a dam, suspended from a platform 225 ft over the side of the dam. The platform was suspended by a crane that did not have its outriggers extended. The load of the crane was overextended and tipped over the dam wall. The two employees in the suspension personnel platform were dropped to the water below. When the platform struck the wall the cable holding the scaffold snapped, causing the employees and platform to fall and sink in the 25 foot water. Both employees were killed.

Keywords: Broken Cable, Crane, Dam, Elevated Work Platform, Struck By, Suspended Load, Water

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1060347.015 55 M Fatality
2 1060347.015 46 M Fatality

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close