Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 762450 - Employees injured when elevator free falls to pit

Accident Summary Nr: 762450 -- Report ID: 0453710 -- Event Date: 05/20/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
1848700905/21/199122110Fieldcrest Cannon, Inc. Plant #1
Inspection NrDate OpenedSICNAICSEstablishment Name
1848701705/21/199117960Piedmont Elevator Co.
Inspection NrDate OpenedSICNAICSEstablishment Name
1848702505/24/199135340The Park Manufacturing Co.
Inspection NrDate OpenedSICNAICSEstablishment Name
1848700905/21/199122110Fieldcrest Cannon, Inc. Plant #1

Abstract: Fourteen employees were riding a freight elevator when a bearing failed, causing the wire rope to jump off the counterweight sheave. The counterweight fell, causing the elevator to fall approximately 45 feet to the pit. One car safety was broken and did not operate; the second safety did not hold. The employees sustained broken feet, legs, ribs, and vertebrae, and bruises.

Keywords: ELEVATOR, FOOT, BEARING, FALL, VERTEBRA, EQUIPMENT FAILURE, RIB, CONTUSION, LEG, FRACTURE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 18487009 Hospitalized injury Fracture Miscellaneous textile machine operators
2 18487009 Hospitalized injury Fracture Miscellaneous textile machine operators
3 18487009 Hospitalized injury Fracture Miscellaneous textile machine operators
4 18487009 Hospitalized injury Fracture Miscellaneous textile machine operators
5 18487009 Hospitalized injury Fracture Miscellaneous textile machine operators
6 18487009 Hospitalized injury Fracture Miscellaneous textile machine operators
7 18487009 Hospitalized injury Fracture Miscellaneous textile machine operators
8 18487009 Hospitalized injury Fracture Miscellaneous textile machine operators
9 18487009 Hospitalized injury Fracture Miscellaneous textile machine operators
10 18487009 Hospitalized injury Fracture Miscellaneous textile machine operators
11 18487017 Occupation Not Listed
12 18487025 Occupation Not Listed
13 18487009 Hospitalized injury Fracture Miscellaneous textile machine operators
14 18487009 Hospitalized injury Fracture Miscellaneous textile machine operators
15 18487009 Hospitalized injury Fracture Miscellaneous textile machine operators
16 18487009 Hospitalized injury Fracture Miscellaneous textile machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close