Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 759993 - ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU PILE LEAD

Accident Summary Nr: 759993 -- Report ID: 0453710 -- Event Date: 02/20/1992
Inspection NrDate OpenedSICNAICSEstablishment Name
1853540102/20/199216290Southern Foundation, Inc.

Abstract: A FOREMAN, A CRANE OPERATOR, AND A CONSTRUCTION WORKER WERE DRIVING CONCRETE PILING. THE BATTER PILE DRIVEN PILING WAS BEING PLACED AT THE SOUTH END OF A JOBSITE NEAR AN OVERHEAD POWER LINE. THE PILING HAD BEEN LIFTED INTO THE LEADS OF THE PILE DRIVER BY A PILE LINE. THE TOP OF THE LEADS EXTENDED OVER THE POWER LINE. THE PILE LINE DRUM BRAKE HAD BEEN DISENGAGED, ALLOWING THE PILE LINE TO RUN OUT FREELY AS THE PILE WAS BEING DRIVEN. WHEN THE PILING WAS 85 PERCENT DRIVEN, THE CONSTRUCTION WORKER DISENGAGED THE PILE LINE FROM THE PILING AND ALLOWED IT TO SWING FREE. THE PILE LINE CONTACTED THE GROUND AND THEN THE POWER LINE. THE CONSTRUCTION WORKER, WHO WAS STANDING ABOUT 3 FEET FROM THE PILE LINE, RECEIVED AN ELECTRIC SHOCK FROM THE POTENTIAL GRADIENT IN THE EARTH.

Keywords: PILE LEADS, OVERHEAD POWER LINE, ELECTRICAL, PILE DRIVER, POTENTIAL GRADIENT, E C, ELECTRIC SHOCK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 18535401 Non Hospitalized injury Electric Shock Construction trades, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.