Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 759050 - Employee's fingers amputated/crushed in punch press

Accident Summary Nr: 759050 -- Report ID: 0551800 -- Event Date: 05/19/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
10859813705/29/199034990Carlisle Tar And Rubber Wheel Plant

Abstract: At 6:30 p.m. on May 19, 1990, Employee #1 was operating a #6 Federal 125-ton punch press. She was equipped with her pull backs (safeties). She was placing wheel rims onto the die plate when she leaned against the unguarded palm buttons, activating the press. Her fingers were trapped between the part and the bottom of the die. Her left little finger was amputated at the second joint and her ring finger was crushed.

Keywords: DIE, AMPUTATED, HAND CONTROL, FINGER, EQUIPMENT FAILURE, CRUSHED, POINT OF OPERATION, PUNCH PRESS, UNGUARDED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 108598137 Hospitalized injury Amputation Punching and stamping press machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.