Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 755595 - Employee killed when struck by boom

Accident Summary Nr: 755595 -- Report ID: 0653510 -- Event Date: 12/19/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
11513907312/19/199417910Hughes & Associates

Abstract: Employee #1 was rigging metal roof decking material to a 22-ton mobile hydraulic crane. A helper signaled the crane operator to pick up the load when suddenly there was a loud pop and the crane began to tip over. An outrigger had failed on the crane. Employee #1 ran toward a building. The boom with a fly extension fell on top of Employee #1 as he was attempting to escape through a structural steel opening of the building. Employee #1 was killed.

Keywords: OUTRIGGER, CRANE BOOM, CONSTRUCTION, EQUIPMENT FAILURE, BACK, STRUCK BY, CONTUSION, HYDRAULIC CRANE, OVERTURN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 115139073 Fatality Bruise/Contus/Abras Structural metal workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.