Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 75207.015 - Employee is killed in fall

Accident Summary Nr: 75207.015 -- Report ID: 0257240 -- Event Date: 03/20/2015
Inspection NrDate OpenedSICNAICSEstablishment Name
1048666.01503/20/2015236220Jovan Inc

Abstract: At 7:45 a.m. on March 20, 2015, an employee was working in the operation of concrete shot. The employee tripped while carrying a steel rod and fell from a high of 28 feet. The employee sustained severe body trauma and was killed.

Keywords: Concrete Beam, Fall, Floor Opening, Tripped
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other building New project or new addition $250,000 to $500,000 3 28 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 1048666.015 52 M Fatality Carpenter Distance of Fall: 28 feet
Worker Height Above Ground/Floor: 28 feet
Cause: Pouring concrete floor at grade
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close