Accident Report Detail

Accident Summary Nr: 745208 - Employee injured when struck by order picker

Accident Summary Nr: 745208 -- Report ID: 0352440 -- Event Date: 06/02/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
10438409406/03/198850990Commerce Distributors, Inc.

Abstract: Employee #1 was in a wholesale distribution warehouse containing lawn and garden supplies and building hardware such as door knobs, locks, hinges, and housewares. He was pulling a four-wheel hand cart loaded with cartons and was heading toward a heavily traveled 90 degree turn around the end of a line of shelving. At the same time, an empty order picker approached the corner. As soon as the order picker rounded the corner, he saw Employee #1 an estimated 8 ft away and hit the deadman pedal, which cut off the electric power and set the brakes. By the time the cart stopped (which should have taken no more than 5 ft) the front of the order picker reached Employee #1 and pinned him between it and the hand cart pull bar. Employee #1 was hospitalized with strains/sprains to his back and shoulders, but he sustained no fractured bones or internal injuries. Rider truck platform trucks, motorized hand and hand/rider trucks, reach trucks, order pickers trucks, hand pallet jacks, and four wheel hand carts are used in the warehouse.

Keywords: SHOULDER, WAREHOUSE, DEADMAN CONTROL, CAUGHT BETWEEN, COLLISION, INDUSTRIAL TRUCK, SHARP TURN, SPRAIN, CART, WARNING SIGN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 104384094 Hospitalized injury Strain/Sprain Freight, stock and material handlers, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.