Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 742346 - Employee's fingers crushed when caught between rollers

Accident Summary Nr: 742346 -- Report ID: 0352430 -- Event Date: 05/09/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
10437362605/31/198826570Maryland Paper Box Company Inc.

Abstract: Employee #1 was attempting to remove a jammed cardboard box from a model Mark K mercury folding carton machine when he stepped on a foot pad 2 ft off the ground. Oil from a leaking gear box was on the bottoms of his shoes and he slipped, becoming caught between the nip rollers. Employee #1's fingers were crushed and he was hospitalized. Employee #1 had received training in operating the machine; however, the troubleshooting and safety training he received was limited.

Keywords: FINGER, WORK RULES, SLIP, JAMMED, ROLLER--MACH/PART, CAUGHT BETWEEN, CRUSHED, SLIPPERY SURFACE, NIP POINT, UNTRAINED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 104373626 Hospitalized injury Strain/Sprain Folding machine operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.