Accident Summary Nr: 741553 - Employee injured when struck by falling metal part

Accident Summary Nr: 741553 -- Report ID: 0352420 -- Event Date: 03/07/1989
Inspection NrDate OpenedSICNAICSEstablishment Name
10840969903/28/198917960B E K-Danco Construction Co., Inc.

Abstract: Employee #1 was replacing numerous components within a paper mill to rebuild it. While welding on a structural beam from a ladder, he was struck by a metal part that fell from approximately 40 ft overhead. Employee #1 fell from the ladder and required hospitalization. Employees were wearing hard hats and eye protection. It was found that the bolts had been removed from the metal part on both ends. The proper rigging had not been put in place to secure the part. Vibration from all the work going on made the part dislodge from its position and fall to the basement, where it struck Employee #1 and injured his pelvis, elbow, and knee.

Keywords: UNSECURED, WORK RULES, CONSTRUCTION, WELDING, VIBRATIONS, PELVIS, FALL, STRUCK BY, FALLING OBJECT, MILL--PLANT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 108409699 Hospitalized injury Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close