Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 73937.015 - Employee is crushed when masonry wall collapses

Accident Summary Nr: 73937.015 -- Report ID: 0523300 -- Event Date: 02/20/2015
Inspection NrDate OpenedSICNAICSEstablishment Name
1041434.01502/20/2015238120Badgerland Metal Building Erectors, Inc.

Abstract: At approximately 7:30 a.m. on February 20, 2015, three iron workers were erecting a steel stairway on a multi-story apartment and retail building. The stairway was being erected inside a shaft that consisted of masonry walls on three sides. The iron workers had rigged a horizontal wire rope between to the east and west walls of the shaft near the top of the shaft on the 3rd floor. A ? ton Harrington Chain Hoist (Model CF4) was supported by the horizontal wire rope and the hoist was used to lift the steel staircase members that weighed between 28-and-123 pounds. The first two levels of the stairway were placed with this system on February 16 & 17, and work did not continue on February 18 & 19 due to extreme winter conditions. On the morning of February 20, the temperature was approximately 8 degrees Fahrenheit, with wind speeds of approximately 7 mph and max gusts of approximately 28 mph. The three iron workers were working from the first floor of the stairwell and were attempting to lift a stair stringer and then lower it for stairway access to the basement. The west section of the 3rd floor masonry wall that was supporting the horizontal wire rope collapsed into the stairwell. Iron worker #1 was welding from an 8 foot tall Werner step ladder that was on the first floor, leaning against the east wall. The collapsing section of wall that was approximately 11 blocks high and 7.5 blocks wide, struck iron worker #1 causing fatal injuries. The masonry walls had been erected for the first 3 floors a couple weeks prior to the accident, but the masonry walls were not complete and were planned to be extended for the remaining floors in the future. The masonry walls had also not been filled with grout nor had the permanent rebar been installed. The masonry wall was attached to the wood structure of the building, but the top portion was greater than 8 feet tall and was not braced to prevent overturning or collapse. A determination was not made to assure that the masonry walls could adequately support the rigging method used for the stairway. Iron worker #1 received crushing injuries to the head, spine, back, and ribs area, and was killed.

Keywords: Construction, Masonry Wall, Struck By, Structural Collapse
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition   3 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Construction
1 1041434.015 58 M Fatality Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Steel Erection Of Solid Web-Welding/Burning/Grindi
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.