Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 738252 - ELECTRIC SHOCK - CONTACT WITH ENERGIZED PARTS

Accident Summary Nr: 738252 -- Report ID: 0452110 -- Event Date: 05/18/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
279044205/23/198820990Mesa Food Products Inc

Abstract: An employee was removing a 240-volt twist-lock receptacle in a wet area. He received an electric shock and was hospitalized for his injury.

Keywords: E GI III, ELECTRICAL, ATTACHMENT PLUG, ELECTRIC SHOCK, WATER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2790442 Hospitalized injury Electric Shock Supervisors; handlers,equip-cleaners,laborers nec

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close