Accident Summary Nr: 737197 - NITRIC ACID ACCIDENTALLY SPILLED ON EMPLOYEE

Accident Summary Nr: 737197 -- Report ID: 0452110 -- Event Date: 06/20/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
1862200106/21/198533690Ken-Dec Inc

Abstract: EMPLOYEE #1 WAS LOOKING FOR AN ELECTRICAL MOTOR STORED IN A CABINET IN THE LABORATORY. A GALLON BOTTLE OF NITRIC ACID FELL FROM AN UPPER SHELF ONTO EMPLOYEE #1'S BACK. THE ACID SPILLED ONTO EMPLOYEE #1, INFLICTING CHEMICAL BURNS OVER 70% OF HIS BODY. THE ACCIDENT WAS CAUSED BY IMPROPER STORAGE OF THE ACID AND LACK OF APPROPRIATE SAFETY WARNINGS.

Keywords: BURN, BACK, CHEMICAL BURN, NITRIC ACID, SKIN, SPILL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 18622001 Hospitalized injury Burn(Chemical) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.