Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 735498 - BOOM OF CRANE FELL ON EMPLOYEE DURING DISASSEMBLY

Accident Summary Nr: 735498 -- Report ID: 0454510 -- Event Date: 08/07/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
10542718108/12/198616220Marchant Construction Co., Inc.

Abstract: EMPLOYEE #1 WAS POSITIONED UNDER THE BOOM OF A MODEL 597C AMERICAN CRANE, SERIAL NUMBER GS16770, WHILE HE WAS DISMANTLING THE BOOM. THE BOOM WAS NOT BLOCKED OR BRACED. WHEN HE REMOVED THE LAST SECTION PIN, THE BOOM FELL ON HIM, CAUSING CRUSHING INJURIES TO HIS LEG, ARM AND SHOULDER.

Keywords: SHOULDER, DISMANTLING, BLOCKS, CRANE BOOM, CRUSHED, STRUCK BY, ARM, BRACING, CRANE, LEG

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 105427181 Hospitalized injury Fracture Construction laborers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close