Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 724021 - Employee dies in aluminum powder explosion

Accident Summary Nr: 724021 -- Report ID: 0521700 -- Event Date: 08/21/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
10871906308/23/199333990Alcan Toyo America

Abstract: A broom stick with a metal end fell into a model #74-865 Continental Rollo mixer containing aluminum powder. While Employee #1 attempted to unload the mixer, it exploded. The possible causes of the initial spark and/or heat were the foreign material in the mixer or misaligned mixer parts. Employee #1 was approximately 3 feet from the mixer and was burned over 85 to 90 percent of his body. He died from his injuries.

Keywords: BURN, ALUMINUM DUST, BROOM, MIXER, EXPLOSION, SPARK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 108719063 Fatality Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.