Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 723833 - Employee drowns when air line becomes entangled

Accident Summary Nr: 723833 -- Report ID: 0521700 -- Event Date: 03/14/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
10345312203/15/199373890Lindahl Marine Contractors

Abstract: Employee #1 was working underwater removing sludge from a 15 foot deep enclosed pit. His air line became entangled in the impeller of one of the three pumps used to keep the water level down in the sludge building. The impeller had a screen guard around it; however, the air line slipped between the guard and the flange of the impeller piping and then wrapped around the impeller rod, thus eliminating the air supply to Employee #1. He drowned.

Keywords: CLEANING, DIVING, DROWN, ENTANGLED, AIR LINE, WATER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 103453122 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.