Accident Summary Nr: 723759 - Employee killed in escalator

Accident Summary Nr: 723759 -- Report ID: 0521700 -- Event Date: 01/25/1993
Inspection NrDate OpenedSICNAICSEstablishment Name
10345259501/26/199317960Montgomery Elevator

Abstract: Employee #1 was changing an electromagnetic brake disc on an escalator motor. He had disconnected the wire to one motor but not the other. Thinking both motors were de-energized, he instructed his helper to turn on the switch to energize the electromagnetic brake so Employee #1 could replace the disc. Employee #1 was sitting on the escalator steps over the motors when they were activated. He was dragged into the unit and his chest was crushed between the step and the walk-off platform. Employee #1 was killed.

Keywords: CHEST, MAINTENANCE, WORK RULES, CONSTRUCTION, LOCKOUT, CAUGHT BETWEEN, CRUSHED, ESCALATOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 103452595 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.