Accident Summary Nr: 709337 - Employee welding in manhole has elevated carboxyhemoglobin

Accident Summary Nr: 709337 -- Report ID: 0854910 -- Event Date: 04/09/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
10209100604/09/198696210Salt Lake Dept. Of Public Utilities

Abstract: Employee #1 was working in a manhole that was 4 ft deep by about 4 ft in diameter. He was using an oxygen-acetylene unit with a burning assembly to cut old bolts and nuts from a water meter. He felt sick that night after work and went to the hospital where his carboxyhemoglobin level was found to be 22 percent.

Keywords: OXYGEN DEFICIENCY, ACETYLENE TORCH, CONFINED SPACE, WORK RULES, INHALATION, TORCH, CARBOXYHEMOGLOBIN, MANHOLE, CARBON MONOXIDE, CUTTING AND BURNING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 102091006 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.