Accident Summary Nr: 708933 - CRANE OVERTURNED, PINNING OPERATOR

Accident Summary Nr: 708933 -- Report ID: 0854910 -- Event Date: 12/12/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
10208408412/12/198517910Adams & Smith Inc

Abstract: EMPLOYEE #1 WAS OPERATIONG AN 18 TON MOBILE HYDRAULIC CRANE, GROVE MODEL RT 518. HE WAS IN THE PROCESS OF MOVING A SECTION OF A CONVEYOR SYSTEM, WEIGHING APPROXIMATELY 3,000 POUNDS, FROM THE SIDE OF A HILL DOWN TO THE LEVEL. AS THE LIFT WAS STARTED, THE LOAD APPARENTLY WAS PULLED SIDEWAYS OFF THE HILL (WITHOUT BEING LIFTED). THIS CAUSED THE LOAD TO SWING BACK AND FORTH. ON THE SECOND SWING, THE CRANE TIPPED OVER ONTO ITS LEFT SIDE. THE OPERATOR WAS PINNED IN THE CAB. THE OUTRIGGERS HAD BEEN EXTENDED ON THE RIGHT (LIFTING) SIDE OF THE CRANE, BUT NOT ON THE LEFT SIDE.

Keywords: OUTRIGGER, CRANE, HYDRAULIC CRANE, OVERTURN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 102084084 Hospitalized injury Fracture Structural metal workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.