Accident Summary Nr: 708024 - STRUCK BY FLYING PIECE OF LUMBER THROWN BY RADIAL ARM SAW

Accident Summary Nr: 708024 -- Report ID: 0352460 -- Event Date: 08/28/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
285294509/10/198692110State Highway Administration (Hagerstown Shop)

Abstract: AT APPROXIMATELY 11:15 AM, ON AUGUST 28, 1986, THE ROAD MAINTENANCE SUPERVISOR WAS RIPPING 3 TO 4 FOOT PIECES OF 2 BY 4 LUMBER ON A DEWALT-BLACK & DECKER RADIAL ARM SAW, SERIAL #65070858. THE SAW WAS NOT SET FOR THE WOOD TO BE FED AGAINST THE DIRECTION OF BLADE ROTATION. EMPLOYEE #1 WALKED UP AND STOOD TO THE SAW'S RIGHT (THE OUTFEED SIDE). A PIECE BEING CUT, SPLIT, THEN WAS THROWN OUTWARD WHEN THE SAW BLADE STRUCK A KNOT. EMPLOYEE #1 WAS STRUCK ON THE BACK OF HIS LEFT HAND (RESULTING IN A LARGE CONTUSION AND BLOOD CLOT) AND THE LEFT SIDE OF HIS ABDOMEN (RESULTING IN AN ABRASION). HE WAS EXAMINED, INCLUDING X-RAYS, AT THE WASHINGTON COUNTY HOSPITAL. HE RECEIVED A TETANUS SHOT AND WAS RELEASED.

Keywords: ABDOMEN, WORK RULES, PLANK, SAW, ABRASION, STRUCK BY, FLYING OBJECT, HAND, CONTUSION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2852945 Hospitalized injury Bruise/Contus/Abras Assemblers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close