Accident Summary Nr: 707919 - Employee's fingers amputated by falling crane boom

Accident Summary Nr: 707919 -- Report ID: 0352430 -- Event Date: 11/23/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
10442526911/23/198817510Springer Construction Co., Inc.

Abstract: Employee #1 was installing roof trusses on a two-story house. A crane was being used to lift the trusses to the area in which he was working. During one of the lifts, the pin that connects the lift cylinder to the boom failed, causing the boom to fall. The falling boom caught Employee #1's left hand between the truss and the crane boom, amputating two fingers. Improper inspection of the crane caused the pin failure.

Keywords: AMPUTATED, INADEQUATE MAINT, PIN, CRANE BOOM, FINGER, WORK RULES, CONSTRUCTION, EQUIPMENT FAILURE, FALLING OBJECT, CRANE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 104425269 Hospitalized injury Amputation Carpenter apprentices

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.