Accident Summary Nr: 707802 - Two employees injured when elevator guide rails fall

Accident Summary Nr: 707802 -- Report ID: 0352420 -- Event Date: 04/08/1987
Inspection NrDate OpenedSICNAICSEstablishment Name
1886819004/08/198717960Otis Elevator Co.

Abstract: Employees #1 and #2 and a coworker were attempting to relocate elevator guide rails. Employee #1 was operating two 6 ton coffin chain hoists at the 18 1/2 floor level. The coworker stood on boards midway on the elevator shaft while Employee #2 was at the bottom of the shaft. They were communicating by radio as they attempted to move a stack of 14 guide rails, approximately 16 ft long and suspended a distance of 4 ft, that were to be bolted in at the bottom of the elevator shaft. The rigging at the top resembled an upside down pyramid. A 3/8 in. wire rope, threaded through two holes in a 5/8 in. thick fish plate, supported the guide rails. The 3/8 in. wire rope, which was doubled and clamped, rested on both hooks of the chain hoists. Employee #1 would let off on one hoist and pull up on the other to move the rails laterally. The 3/8 in. wire rope sheared, allowing the rails to fall. Employee #1 suffered internal bruises and Employee #2 suffered a hand injury. Both employees were treated at Mercy Hospital and released.

Keywords: SHEAR, HOISTING MECHANISM, WIRE ROPE, BROKEN CABLE, CONSTRUCTION, EQUIPMENT FAILURE, FALL, HAND, CONTUSION, ELEVATOR SHAFT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 18868190 Hospitalized injury Cut/Laceration Elevator installers and repairers
2 18868190 Hospitalized injury Bruise/Contus/Abras Elevator installers and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close