Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 70128.015 - Employee receives burns and is killed from fly ash released

Accident Summary Nr: 70128.015 -- Report ID: 0213100 -- Event Date: 01/23/2015
Inspection NrDate OpenedSICNAICSEstablishment Name
1020528.01501/24/2015322121International Paper Company

Abstract: At approximately 8:30 a.m. on January 23, 2015, an employee was climbing a fixed ladder to change filter bags on the bag house. While changing, fly ash was released from the bagger or silo. The employee caught on fire and died as a result of extensive burns.

Keywords: Burn, Combustible Dust, Explosion, Fixed Ladder, Silo

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 1020528.015 57 M Fatality

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close