Accident Report Detail
Accident Summary Nr: 69869.015 - Worker is killed when crushed by moving pipe layer.
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 1017249.015 | 01/10/2015 | 237120 | Snelson Companies, Inc. |
Abstract: At 1:45 p.m. on January 10, 2015, Employee #1, employed by a pipeline construction services company, was engaged in laying pipe. He was operating a Caterpillar 572H Pipe Layer. He started up the Caterpillar and then stood on one of the vehicle's tracks. The vehicle began to roll backwards down a slope. Employee #1 was pulled feet first under the side boom frame extending over the track. He was pulled into a 6-inch clearance up to his waist. Employee #1 was killed when his internal organs were crushed. This fatality was investigated by West Virginia OSHA.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Pipeline | New project or new addition | $5,000,000 to $20,000,000 | 0 | X | |||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 1017249.015 | 57 | M | Fatality | Equipment Operator: Heavy | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Trenching, installing pipe Fatality Cause: |
Translate