Accident Summary Nr: 694158 - Employee killed in fall from unguarded scaffold

Accident Summary Nr: 694158 -- Report ID: 0355114 -- Event Date: 12/24/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
335004812/24/198517410Beacon Masonry Corporation
Inspection NrDate OpenedSICNAICSEstablishment Name
335005501/02/198615420Eugene Thomas Construction Co., Inc.

Abstract: At approximately 10:50 a.m. on December 24, 1985, Employee #1 was working on the seventh buck level of a 75 ft long tubular welded frame scaffold, preparing to raise the scaffold boards to the next level. He was approximately 42 to 45 ft above ground and adjacent to the fourth floor of a 5-floor office building under construction. The scaffold had no midrail installed as part of the guardrail system. Employee #1 was walking toward the north end of the scaffold along the outermost plank when he stepped across the third buck from the north end. The board he stepped from overlapped the end board and he could not see that the end board did not overlap the buck. The end board tipped up and down and he fell to the ground, landing on his head. Employee #1 died of severe head injuries. A few days prior, a gust of wind had blown the end board down and Employee #1 had put it back in place. The improperly reinstalled board plus the lack of a midrail were apparently the causes of the accident.

Keywords: HEAD, UNSECURED, WORK RULES, MIDRAIL, GUARDRAIL, INADEQUATE MAINT, CONSTRUCTION, FALL, SCAFFOLD, TUBULAR SCAFFOLD

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 3350048 Fatality Concussion Construction laborers
2 3350055 Occupation Not Listed

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.