Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 691493 - Employees injured when scaffold collapses

Accident Summary Nr: 691493 -- Report ID: 0854910 -- Event Date: 07/01/1988
Inspection NrDate OpenedSICNAICSEstablishment Name
10558550907/11/198817210The Gateway Co

Abstract: Employees installed a two-point suspension scaffold from which they were to paint a 40 ft high water tank. The safety lines provided were only 50 ft long and not long enough to tie to the structure and reach the ground. The lines were secured to the tie cables above the edge roller. The pin securing the scaffold rigging broke at the weld line, releasing the scaffold's rigging. The scaffold collapsed and fell about 36 to 38 ft, carrying Employees #1 and #2 with it to the ground. The employees were hospitalized.

Keywords: RIGGING, BROKEN WELD, CONSTRUCTION, EQUIPMENT FAILURE, SCAFFOLD COLLAPSE, TWO PT SUSP SCAFFOLD, FALL, FALL PROTECTION, WATER TANK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 105585509 Hospitalized injury Fracture Painters, construction and maintenance
2 105585509 Hospitalized injury Fracture Painters, construction and maintenance

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close