Accident Summary Nr: 690057 - Two employees killed in fall with scaffold

Accident Summary Nr: 690057 -- Report ID: 0552700 -- Event Date: 10/11/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
291482810/11/198517210Sholings Sandblasting & Painting

Abstract: On October 11, 1985, Employees #1 and #2 were inside a water tank, working from a two-point suspension scaffold when its improperly rigged suspension system caused the south lines to come apart. The scaffold swung like a pendulum, dumping Employees #1 and #2 and causing the north cable to slip through the wire rope clips and the scaffold to fall 105 ft to the tank floor. Employees #1 and #2 suffered severe head trauma and were killed.

Keywords: HEAD, UNSECURED, WORK RULES, CONSTRUCTION, SCAFFOLD COLLAPSE, TWO PT SUSP SCAFFOLD

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2914828 Fatality Fracture Painters, construction and maintenance
2 2914828 Fatality Fracture Painters, construction and maintenance

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.