Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 689729 - Employee killed during trench cave-in

Accident Summary Nr: 689729 -- Report ID: 0552700 -- Event Date: 08/19/1985
Inspection NrDate OpenedSICNAICSEstablishment Name
291349908/19/198516230Barbarossa And Sons Inc

Abstract: Employee #1 had examined a section of pipe casing at the bottom of a trench excavation and decided to cut off a section of the pipe. As he lay prone, the west wall collapsed, trapping him. Employee #1 suffocated and died.

Keywords: EXCAVATION, SUFFOCATED, WORK RULES, CONSTRUCTION, TRENCH, UNSTABLE SOIL, BURIED, CAVE-IN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 2913499 Fatality Asphyxia Operating engineers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.