Accident Summary Nr: 68309.015 - Two Employees are killed from chemical burns

Accident Summary Nr: 68309.015 -- Report ID: 0316400 -- Event Date: 09/19/2014
Inspection NrDate OpenedSICNAICSEstablishment Name
997653.01510/01/2014325180Eagle Natrium, Llc

Abstract: At 2:45 p.m. on September 19, 2014, two employees were replacing a valve in a process line that transported 70 percent caustic solution of sodium hydroxide from storage tanks to a loading rack. While they were removing the valve and a stopper plate that had been previously inserted into the line, the employees were sprayed with the caustic solution. The workers suffered chemical burns to their skin and lungs, resulting in their death.

Keywords: Chemical, Chemical Burn, Lung, Sodium Hydroxide

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 997653.015 50 M Fatality Mechanical controls and valve repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.