Accident Summary Nr: 674127 - Employee dies of asphyxia in pressure vessel

Accident Summary Nr: 674127 -- Report ID: 0454510 -- Event Date: 05/09/1991
Inspection NrDate OpenedSICNAICSEstablishment Name
11566264505/09/199135450Carmet Company

Abstract: Employee was removing a load from a 26 in. diameter hot isostatic press (HIP) pressure vessel with a 9 ft space from the opening to the heat pedestal at the bottom, when graphite spacers fell from the graphite plates that held the tungsten metal parts to the bottom of the HIP vessel. Because the next load would not fit with the spacers in the bottom, Employee #1 was sent down to get them. He was retrieving the second spacer when he was overcome by argon gas. The HIP pressure vessel is used to cure tungsten steel at a temperature of 1,360 degrees C and a pressure of 15,000 psi, using argon gas. The vessel atmosphere had not been tested or ventilated prior to entry; employees had no training; and no rescue procedures with lifelines and respiratory equipment were available. Employee #1 died of asphyxia.

Keywords: ASPHYXIATED, VENTILATION, PRESSURE VESSEL, WORK RULES, INHALATION, GAS, OVEREXPOSURE, ARGON

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 115662645 Fatality Asphyxia Furnace, kiln and oven operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close