Accident Report Detail

Accident Summary Nr: 674119 - EMPLOYEES INJURED IN CHEMICAL SPILL

Accident Summary Nr: 674119 -- Report ID: 0454510 -- Event Date: 08/22/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
11101660608/23/199028690Albright & Wilson Americas, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
11101664809/19/199017310Instrument Control Service
Inspection NrDate OpenedSICNAICSEstablishment Name
11101663009/19/199015400Aetna Building Restoration
Inspection NrDate OpenedSICNAICSEstablishment Name
11101661408/23/199017910Thompson Industrial Services
Inspection NrDate OpenedSICNAICSEstablishment Name
11101660608/23/199028690Albright & Wilson Americas, Inc.

Abstract: Employees #1, #2, #3 and #4 were working for a subcontractor in a chemical plant. They were working on a scaffold, fitting pipe, directly above a chemical tank where phosphorus tri-chloride was being transferred. A chemical spill occurred when a chemical operator transferred phosphorus tri-chloride from one chemical tank to another. A low point drain valve on the second tank was open allowing the spilled phosphorus tri-chloride to react with ground water. This reaction formed hydrochloric acid vapor and also causing an explosion. Employees #1, #2, #3 and #4 were exposed to chemical vapor and suffered from lung irritation. Employees #1, #2, #3 and #4 required medical assistance and were examined and evaluated by paramedics on site. Employee #3 was hospitalized. The other employees were treated but not hospitalized. The subcontracting employer of did not provide escape respirators or a written emergency procedures covering use of such respirators. (This accident is the same as #000674101.)

Keywords: ASPHYXIATED, HYDROCHLORIC ACID, POISONING, CHEMICAL, LUNG, CHEMICAL REACTION, CHEMICAL VAPOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 111016606 Non Hospitalized injury Poisoning(Systemic) Insulation Workers
2 111016606 Non Hospitalized injury Poisoning(Systemic) Insulation Workers
3 111016606 Hospitalized injury Poisoning(Systemic) Insulation Workers
4 111016648 Occupation Not Listed
5 111016630 Occupation Not Listed
6 111016614 Occupation Not Listed
7 111016606 Non Hospitalized injury Poisoning(Systemic) Supervisors, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.