Accident Summary Nr: 670943 - Employee overexposed to chlorine gas

Accident Summary Nr: 670943 -- Report ID: 0551800 -- Event Date: 07/30/1986
Inspection NrDate OpenedSICNAICSEstablishment Name
10199583507/31/198691900Boonville City Of

Abstract: At 10:15 a.m. on July 30, 1986, Employee #1 was taking water samples to the Boonville water treatment plant. He was told by the plant operator that the indicator lights on the control panel indicated that a well field in eastern Spencer County was shutting on and off. Employee #1 told the plant operator that he would go to the water well field to check the problem. He then fueled his truck and traveled to the site, arriving at approximately 10:35 a.m. He was alone at the site. He left his truck, opened the door of the control room toward him, and smelled chlorine gas. Employee #1 then opened the door of the chlorine gas room. He ran back to his truck, moved it as far as he could, and called the Boonville Fire Department for help at approximately 10:47 a.m. Employee #1 later stated that nothing seemed very clear until he was in the Warrick County Hospital emergency room in Boonville. The building consists of two rooms. The control room is concrete block construction, 88 in. by 96 in. by 104 ft high with an outside steel door and ventilation. The chlorine room is concrete block construction, 120 in. by 96 in. by 104 in. high with an outside steel door, a disconnected chlorinator and electrical system with an outside light/exhaust for a switch, and a corroded, rested pump motor with rust on all inside walls.

Keywords: INADEQUATE MAINT, INHALATION, CHLORINE, CHLORINE ROOM, GAS LEAK, TOXIC FUMES, OVEREXPOSURE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101995835 Hospitalized injury Asphyxia Water and sewage treatment plant operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close