Inspection NrDate OpenedSICNAICSEstablishment Name
10183367103/07/198648130New England Telephone Company

Abstract: A telephone line worker was installing a telephone cable from the bucket of an aerial lift. The ServiLift aerial lift (Model No. S-21 MT, Serial No. 7&2), which had a load rating of 136 kilograms, was manufactured in 1970. It had an articulating boom, and the fiberglass-reinforced plastic upper boom was refurbished in 1980. When employee had finished at one work location, the truck was driven back with no tension or additional stress on the boom beyond the weight of the employee. The upper boom cracked at the rotating hinge area, where the stress is the greatest. The line worker grabbed onto some tree branches and apparently fell into his safety belt. He injured the back of his neck and suffered severe sprains. He was hospitalized for his injures. It is believed that sufficient inspections would have uncovered defects in the boom.

Keywords: TELECOM WORK, BOOM, EQUIPMENT FAILURE, FALL, FALL PROTECTION, NECK, SPRAIN, AERIAL LIFT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101833671 Hospitalized injury Bruise/Contus/Abras Telephone line installers and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close