Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 644112 - Employee killed when burned by flashing propane and oxygen

Accident Summary Nr: 644112 -- Report ID: 0215000 -- Event Date: 08/22/1990
Inspection NrDate OpenedSICNAICSEstablishment Name
10994096508/22/199037310N.Y. Shipyard Corp.
Inspection NrDate OpenedSICNAICSEstablishment Name
10994095708/22/199037310Voyage Industrial Services

Abstract: A crimped oxygen and propane hose was left in a cofferdam during lunch. The gases were not shut off at the manifold. Employee #1, an arc welder, returned to the area after lunch to arc weld a bleed-off plug into place. When he started welding, the accumulated fuel gas and oxygen flashed and burned him. He died. No tests for flammable vapors and oxygen were performed and no ventilation was provided.

Keywords: BURN, OXYGEN, OPEN VALVE, VENTILATION, FLAMMABLE VAPORS, WORK RULES, FIRE, PROPANE, ARC WELDING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 109940965 Occupation Not Listed
2 109940957 Fatality Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.