Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 642652 - Employee killed in empty tank explosion

Accident Summary Nr: 642652 -- Report ID: 0215800 -- Event Date: 08/10/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
10155011908/10/199417990Industrial Oil Tank Services Corporation

Abstract: At approximately 11:56 a.m. on August 10, 1994, Employee #1 was cutting into the end of an empty 6,000-gallon gasoline tank using a gasoline powered target saw. The tank exploded. Employee #1 died.

Keywords: FLAMMABLE VAPORS, CONSTRUCTION, EXPLOSION, TANK, CUTTING AND BURNING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 101550119 Fatality Concussion Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.