Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 638999 - Employee dies in elevator free-fall

Accident Summary Nr: 638999 -- Report ID: 0216000 -- Event Date: 06/16/1994
Inspection NrDate OpenedSICNAICSEstablishment Name
11393999506/16/199417960Dover Elevator Company, Inc.

Abstract: On June 16, 1994, Employee #1 was working from atop the crosshead of a traction elevator car-sling which was suspended from the machine room at the R-3 level, 60 ft above the elevator pit. The elevator car-sling was hoisted to the R-3 level by a Dallas hoist machine without the governor being roped and without ensuring that the elevator car's safeties were operational. A 5/8 in. sling was installed around the crosshead and an adjacent rail bracket. The sling was unpadded and when the Dallas hoist cable was removed, the 5/8 in. sling failed and the elevator car-sling free-fell. Due to the elevator's governor not being installed and roped, the elevator car's safeties did not actuate in order to stop the car. Employee #1 free-fell with the car-sling 60 ft to the pit and died.

Keywords: UNSECURED, WORK RULES, CONSTRUCTION, EQUIPMENT FAILURE, FALL, SLING, ELEVATOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 113939995 Fatality Fracture Construction trades, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close